e142. M1090/M1094 TAILGATE RELEASE DOES NOT OPERATE
INITIAL SETUP
Equipment Conditions
Materials/Parts
Engine shut down (TM 9-2320-366-10-1).
Wire, Elec, 50ft (Item 71, Appendix D)
Tools and Special Tools
Personnel Required
Tool Kit, Genl Mech (Item 46, Appendix C)
(2)
STE/ICE-R (Item 41, Appendix C)
References
Multimeter, Digital (Item 22, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
TM 9-4910-571-12&P
START
WARNING
CAUTION
Read WARNING and
CAUTION on
KNOWN INFO
TEST OPTIONS
following page.
1.
Dump bed raises and lowers.
Voltage Test or
Pneumatics system OK.
STE/ICE-R Test #89
Is 24 VDC present at
POSSIBLE PROBLEMS
REASON FOR QUESTION
connector L7 socket 1?
This question eliminates
Faulty tailgate release
possible problems and
determines where
Faulty tailgate release
troubleshooting continues.
switch.
Faulty auxiliary panel cable
assembly.
Faulty dump power cable
assembly.
NO
Faulty dump cable assembly.
YES
Go to step 3 of this fault.
Change 1