TM 9-2320-366-20-2
e139. MAIN WINCH LH OR RH SPEED SWITCH DOES NOT OPERATE FROM WRECKER
CONTROL PANEL (CONT)
KNOWN INFO
TEST OPTIONS
3.
LH and RH winches operate
Continuity Test or
from wrecker control panel.
STE/ICE-R Test #91
Is continuity present from
Circuit breaker CB50 OK.
REASON FOR QUESTION
terminal lug on wire C to
STATION SELECTOR switch to
This question eliminates
ground?
WRECKER CONTROL PANEL.
possible problems and
MODE SELECTOR SWITCH to
determines where
NORMAL.
troubleshooting continues.
STATION SELECTOR switch
OK.
NO
MAIN WINCH LH SPEED
switch OK.
M1089 control panel power
cable assembly OK.
M1089 rear lights cable
assembly.
YES
Go to step 8 of this fault.
Auxiliary panel cable assembly
OK.
Dashboard cable assembly OK.
MAIN WINCH RH SPEED
switch OK.
M1089 control panel wiring
harness OK.
POSSIBLE PROBLEMS
Faulty M1089 30K winch
control wiring harness.
Faulty jumper wire.
Faulty wrecker hydraulic
system.
Notify DS Maintenance