TM 9-2320-366-20-2
e138A. M1089 LH OR RH 30K WINCH DOES NOT PAY-IN (CONT)
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
on following page.
2.
Voltage Test or
Hydraulic tank oil level OK.
STE/ICE-R Test #89
Is 24 VDC present at
MAIN WINCH LH and RH FREE
REASON FOR QUESTION
terminal block (see Table
SPOOL switches to OFF.
2-12.20. MAIN WINCH
MODE SELECTOR SWITCH to
If 24 VDC is not present,
LH/RH FREE SPOOL Switch
NORMAL.
perform Wrecker Air System
Terminal Blocks)?
troubleshooting. If 24 VDC is
POSSIBLE PROBLEMS
present, MAIN WINCH LH/RH
FREE SPOOL switch is faulty.
Faulty MAIN WINCH LH/RH
FREE SPOOL switch.
NO
Faulty M1089 air system.
Faulty wrecker hydraulic
system.
Perform Wrecker Hydraulic System
YES
troubleshooting task (aa1. M1089 LH or RH
30K Winch Does Not Pay-In).
Replace MAIN WINCH LH/RH FREE
SPOOL switch (para 7-34).
Change 2
|