TM 9-2320-366-20-2
TM
e120. M1089 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
STE/ICE-R (Item 41, Appendix C)
(2)
References
TM 9-491-571-12&P
START
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
1.
on following page.
Battery voltage OK.
Voltage Test or
Circuit breakers OK.
STE/ICE-R Test #89
Is 24 vdc present at
REASON FOR QUESTION
Power control cable
junction box assembly
assembly OK.
If 24 vdc is not present,
terminal board position 2?
Auxiliary panel cable
crane power cable is
assembly OK.
faulty.
Dashboard cable
assembly OK.
NO
Hydraulic system OK.
POSSIBLE PROBLEMS
Faulty crane power cable.
Faulty junction box
assembly.
Replace crane power
cable (para 7-79).
YES