TM 9-2320-366-20-2
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
STE/ICE-R (Item 41, Appendix C)
(2)
References
TM 9-4910-571-12&P
START
WARNING
Read WARNING
TEST OPTIONS
KNOWN INFO
on following page.
1.
Voltage Test or
Battery voltage OK.
STE/ICE-R Test #89
Circuit breakers OK.
REASON FOR QUESTION
Is input voltage present at
Auxiliary panel cable assembly
junction box terminal board
OK.
Crane will not operate if 24
position 5?
Dashboard wiring harness OK.
VDC is not present at junction
Hydraulic system OK.
box terminal board position 5.
POSSIBLE PROBLEMS
Faulty crane power cable.
Faulty junction box internal
NO
wiring.
Faulty reverse polarity diode(s).
YES
Go to step 2 of this fault.
Perform Electrical Troubleshooting (e115.
M1084/M1086 Material Handling Crane (MHC)
Overload Shutdown System Stays Activated).
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |