e102. M1090/M1094 AIR DRYER DOES NOT OPERATE
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
(2)
References
TM 9-4910-571-12&P
START
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
1.
on following page.
Air lines and fittings OK.
Voltage Test or
STE/ICE-R #89
Is 24 vdc present on
governor OK.
REASON FOR QUESTION
connector P80B-2?
This question eliminates
Dump up indicator OK.
possible problems and
POSSIBLE PROBLEMS
determines where
Faulty air dryer.
troubleshooting continues.
Faulty dashboard
cable assembly.
NO
Faulty start and charging
cable assembly.
Faulty dump cable
YES
Go to step 3 of this fault.
assembly.