TM 9-2320-366-20-2
TM
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Engine shut down (TM 9-2320-366-10-1).
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Personnel Required
Multimeter, Digital (Item 22, Appendix C)
(2)
References
TM 9-4910-571-12&P
START
KNOWN INFO
TEST OPTIONS
1.
Engine fan turns off using
Continuity Test
deep water fording switch.
STE/ICE-R #91
Is continuity present
POSSIBLE PROBLEMS
REASON FOR QUESTION
between water temperature
Faulty water temperature
If continuity is not present,
switch connector
switch.
water temperature switch
terminal 1 and terminal 2?
Faulty dashboard cable
is faulty.
assembly.
Faulty engine control
cable assembly.
NO
Replace water temperature
YES
switch (para 7-50).
|