TM 9-2320-366-20-2
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back or not
capable of making good contact.
CONTINUITY TEST
(1) Lower cab (TM 9-2320-366-10-1).
(2) Remove instrument panel for access
(para 7-15).
(3) Disconnect connector J31 from connector
P31.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter
to relay K11 terminal 87A on PDP.
(6) Connect negative (-) probe of multimeter to
connector J31 pin 1 and note reading on
multimeter.
(7) If continuity is not present, repair wire
568A from connector J31 pin 1 to relay
K11 terminal 87A (para 2-45) on PDP or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(8) If continuity is present, repair wire 568A
from connector P31 socket 1 to terminal
lug TL35 (para 2-45) or replace engine
control cable assembly (para 7-80).
(9) Connect connector J31 to connector P31.
(10) Install instrument panel (para 7-15).
(11) Install relay K11 in PDP.
(12) Install PDP cover (para 16-2).
(13) Connect batteries (para 7-57).
Change 1
|