TM 9-2320-366-20-2
TM
e90. 15K SELF-RECOVERY WINCH (SRW) DOES NOT PAY OUT (CONT)
e90.
KNOWN INFO
TEST OPTIONS
2.
Circuit breaker OK.
Continuity Test or
15K SRW reels in OK.
STE/ICE-R #91
Is continuity present
REASON FOR QUESTION
WINCH IN/OUT switch OK.
between winch out
If continuity is not present,
Auxiliary panel cable
solenoid L5 connector
wire 3070 is faulty. If
assembly OK.
terminal 2 and a known
continuity is present,
PTO cable assembly OK.
good ground?
POSSIBLE PROBLEMS
winch control valve
Faulty winch control valve
assembly is faulty.
cable assembly.
Faulty winch control valve
NO
assembly.
Repair wire 3070 (para 2-45)
YES
or replace winch control valve
cable assembly (para 7-135).
Replace winch control
valve assembly (para 17-25).