TM 9-2320-366-20-2
TM
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Tool Kit, Genl Mech (Item 46, Appendix C)
Engine shut down (TM 9-2320-366-10-1).
STE/ICE-R (Item 41, Appendix C)
Personnel Required
Multimeter, Digital (Item 22, Appendix C)
(2)
References
Materials/Parts
TM 9-4910-571-12&P
Wire, Elect, 50 ft (Item 71, Appendix D)
START
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
1.
Circuit breaker OK.
Voltage Test or
on following page.
PTO OK.
STE/ICE-R #89
Is 24 vdc present on
POSSIBLE PROBLEMS
REASON FOR QUESTION
connector P902 terminal 6?
Faulty auxiliary panel
If 24 vdc is not present,
cable assembly.
wire 1904 is faulty.
Faulty winch power
switch.
NO
Faulty WINCH IN/OUT
switch.
Repair wire 1904 (para 2-45)
YES
or replace auxiliary panel
cable assembly (para 7-58).
|