TM 9-2320-366-20-2
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
pneumatic controller connector pin D.
(3) Connect negative (-) probe of multimeter to
pneumatic controller connector pin B and
note reading on multimeter.
(4) If 30-80 ohms resistance is not present,
replace manifold valve assembly
(para 12-7).
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
pneumatic controller connector pin F.
(3) Connect negative (-) probe of multimeter to
pneumatic controller connector pin A and
note reading on multimeter.
(4) If 30-80 ohms resistance is not present,
replace manifold valve assembly (para 12-7).
Change 2
|