Click here to make tpub.com your Home Page

Page Title: M1089 SOLENOID TEST ADAPTER
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-1
E-8. M1089 SOLENOID TEST ADAPTER
Assemble the M1089 solenoid test adapter according to the following steps. Refer to the following parts list and Figure
E-12. M1089 Solenoid Test Adapter for details.
Part Number
Material Description
National Stock
Qty
Number
2-2-2 080401CA
Tee, Tube
1
2-2 080202CA
Elbow, Pipe to Tube
1
4-2 130140B
Bushing, Pipe
1
NB-2-031
Tubing, Nonmetallic
24 in.
Figure E-12. M1089 Solenoid Test Adapter
a.
All dimensions are in inches (millimeters).
b.
Cut one piece of nonmetallic tubing (1) to 6.0 in. (152.4 mm) long.
c.
Cut one piece of nonmetallic tubing (2) to 18.0 in. (457.2 mm) long.
c.
Remove three nuts (3) and ferrule sleeves (4) from tube tee (5).
d.
Install two nuts (3) and ferrule sleeves (4) on nonmetallic tubing (1).
e.
Install nonmetallic tubing (1) on tube tee (5).
f.
Remove nut (6) and ferrule sleeve (7) from pipe to tube elbow (8).
g.
Install two nuts (3 and 6) and ferrule sleeves (4 and 7) on nonmetallic tubing (2).
h.
Install nonmetallic tubing (2) on tube tee (5).
i.
Install nut (6) on pipe to tube elbow (8).
j.
Install pipe bushing (9) on pipe to tube elbow (8).

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business