TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector PX7-17.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3030
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector PX7-2.
(3)
Connect negative (-) probe of multimeter to
connector PX7-17 and note reading on
multimeter.
(4)
If continuity is not present, replace lighted
indicator display (para 7-16).
(5)
If continuity is present, replace chemical
detector (notify NBC).
(6)
Connect lighted indicator display to connector
PX7.
(7)
Position lighted indicator display in instrument
panel assembly with four screws.
(8)
Tighten four screws to 6-10 lb-in. (1 Nm).
(9)
Connect batteries (para 7-57).
2-941/(2-942 Blank)
2-941/(2-942
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |