e84.
KNOWN INFO
TEST OPTIONS
4.
Start and charging cable
Continuity Test or
assembly OK.
STE/ICE-R #91
Is continuity present
POSSIBLE PROBLEMS
REASON FOR QUESTION
between connector PX7-17
Faulty dashboard cable
If continuity is not present,
and a known good ground?
assembly.
wire 3030 is faulty.
Faulty lighted indicator
display.
Faulty chemical detector.
NO
Repair wire 3030 (para 2-45)
or replace WTEC II dashboard cable
YES
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
KNOWN INFO
TEST OPTIONS
5.
Start and charging cable
Continuity Test or
STE/ICE-R #91
assembly OK.
Is continuity present
REASON FOR QUESTION
Dashboard cable
between connector PX7-2
If continuity is not present,
assembly OK.
and connector PX7-17?
lighted indicator display is
POSSIBLE PROBLEMS
faulty. If continuity is
Faulty lighted indicator
present, chemical detector
display.
is faulty.
Faulty chemical detector.
NO
Replace lighted indicator
YES
display (para 7-16).
Replace chemical detector.
Notify NBC.
2-940
|