TM 9-2320-366-20-1
NOTE-
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Remove instrument panel assembly for
access(para 7-15).
(2) Disconnect connector PX15 from main light
switch.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
main light switch pin F.
(5) Connect negative (-) probe of multimeter to
main light switch pin E.
(6) Position main light switch to BO MARKER
(TM 9-2320-366-10-1) and note reading on
multimeter.
(7) If continuity is not present, replace main light
switch connector (para 7-17).
(8) If continuity is present, repair wire 1572
from connector PX15 socket E to terminal
board TB1 position 56 (para 2-45) or replace
WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(9) Position main light switch to OFF
(TM 9-2320-366-10-1).
(10) Connect connector PX15 to main light
switch.
(11) Install instrument panel assembly (para 7-15).