TM 9-2320-366-20-1
CONTINUITY TEST
(1) Remove two screws, lockwashers, RH
composite taillight assembly, and
terminal lug TL21 from right taillight
carrier. Discard lockwashers.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
terminal lug TL21.
(4) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(5) If continuity is not present, go to step 12
of this fault.
(6) If continuity is present, replace RH
composite taillight assembly (para 7-39).
(7) Install terminal lug TL21, and RH composite
taillight assembly on right taillight carrier with
two lockwashers and screws.
(8) Connect connector P64 to RH composite
taillight assembly.
(9) Install RH composite taillight lamp in socket.
(10) Install preformed packing and cover on RH
composite taillight assembly with six screws.