TM 9-2320-366-20-1
(1) Position main light switch to SER DRIVE
(TM 9-2320-366-10-1).
(2) If RH door marker light lamp does not
illuminate, go to step 4 of this fault.
(3) Position main light switch to OFF
(TM 9-2320-366-10-1).
CONTINUITY TEST
(1) Remove two screws and lens cover from
RH cab marker light base.
(2) Remove RH marker light lamp from socket.
(3) Set multimeter to ohms.
(4) Check continuity through RH marker light
lamp and note reading on multimeter.
(5) If continuity is not present, replace RH
marker light lamp (para 7-38).