Click here to make tpub.com your Home Page

Page Title: CONTINUITY TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1) Remove instrument panel assembly for
access (para 7-15).
(2) Disconnect connector P18 from
connector J18.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to PDP terminal 86, where relay K7 was
removed.
(5) Connect negative (-) probe of multimeter
to connector P18 pin 3 and note reading
on multimeter.
(6) If continuity is not present, repair wire
16 from PDP relay K7 terminal 86 to
connector P18 pin 3 (para 2-45) or
replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(7) If continuity is present, repair wire 16
from connector P16 pin 3 to connector
PX15 socket M (para 2-45) or replace
WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(8) Install relay K7 in PDP.
(9) Install PDP cover (para 16-2).
(10) Connect connector P18 to connector J18.
(11) Install instrument panel assembly
(para 7-15).
Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business