TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Raise cab (TM 9-2320-366-10-1).
(2)
Set multimeter to ohms.
(3)
Disconnect connector clamp from connector
J37.
(4)
Disconnect connector P37 from connector
J37.
(5)
Connect positive (+) probe of multimeter to
connector P37-2.
(6)
Connect negative (-) probe of multimeter to
connector PX7-12 and note reading on
multimeter.
(7)
If continuity is not present, go to step 5 of
this fault.
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector P37-1.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, go to step 6 of
this fault.
(5)
If continuity is present, replace water
temperature switch (para 7-50).
(6)
Connect connector P37 to connector J37.
(7)
Connect connector clamp on connector J37.
(8)
Lower cab (TM 9-2320-366-10-1).
2-415
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |