e24. HIGH ENGINE TEMPERATURE INDICATOR DOES NOT OPERATE (CONT)
e24.
KNOWN INFO
TEST OPTIONS
2.
Other indicator lights
Continuity Test or
operate.
STE/ICE-R #91
Is continuity present
Lighted indicator
REASON FOR QUESTION
between connector PX7-12
display OK.
If continuity is not present,
and connector P37-2?
wire 35 is faulty.
POSSIBLE PROBLEMS
Faulty dashboard cable
assembly.
Faulty engine control
NO
cable assembly.
Faulty water temperature
switch.
YES
Go to step 5 of this fault.
KNOWN INFO
TEST OPTIONS
3.
Other indicator display
Continuity Test or
lights operate.
STE/ICE-R #91
Is continuity present
Lighted indicator
REASON FOR QUESTION
between connector P37-1
display OK.
If continuity is not present,
and a known good ground?
POSSIBLE PROBLEMS
wire 3026 is faulty. If
continuity is present,
Faulty dashboard cable
water temperature switch
assembly.
is faulty.
Faulty engine control
cable assembly.
NO
Faulty water temperature
switch.
YES
Go to step 6 of this fault.
Replace water temperature
switch (para 7-50).