TM 9-2320-366-20-1
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
VOLTAGE TEST
(1) Set multimeter to volts DC.
(2) Connect positive (+) probe of multimeter to
connector P901 socket 2.
(3) Connect negative (-) probe of multimeter to
ground.
(4) Position main light switch main selector
lever to SER DRIVE (TM 9-2320-366-10-1).
(5) Position main light switch auxiliary lever to
PNL BRT (TM 9-2320-366-10-1) and note
reading on multimeter.
(6) If 12 VDC is not present, go to step 3 of
this fault.
(7) If 12 VDC is present, replace tachometer
(para 7-21).
(8) Position main light switch auxiliary lever
to OFF (TM 9-2320-366-10-1).
(9) Position main light switch main selector
lever to OFF (TM 9-2320-366-10-1).
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |