TM 9-2320-366-20-1
CONTINUITY TEST
(1) Disconnect connector PX24 from dimmer
switch.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter
to connector PX15-B.
(4) Connect negative (-) probe of multimeter to
connector PX24-1 and note reading on
multimeter.
(5) If continuity is not present, repair wire
1542 (para 2-45) or replace WTEC II
dashboard cable assembly (para 7-10) or
WTEC III dashboard cable assembly
(para 7-11).
(6) Connect connector PX15 to main light
switch.
CONTINUITY TEST
(1) Position dimmer switch to maximum
illumination (TM 9-2320-366-10-1).
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter
to dimmer switch connector terminal 1.
(4) Connect negative (-) probe of multimeter to
dimmer switch connector terminal 2 and
note reading on multimeter.
(5) If continuity is not present, replace dimmer
switch (para 7-12).
(6) If continuity is present, repair wire 1908
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(7) Connect connector PX24 to dimmer switch.
(8) Install instrument panel assembly
(para 7-15).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |