TM 9-2320-366-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
CONTINUITY TEST
(1) Disconnect connector clamp from OIL
PRESS gage connector.
(2) Disconnect connector PX6 from OIL PRESS
gage connector.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
connector PX6 socket 2.
(5) Connect negative (-) probe of multimeter to
connector PX24 pin 2 and note reading on
multimeter.
(6) If continuity is not present, repair wire 1908
from connector PX6 socket 2 to connector
PX24 socket 2 (para 2-45) or replace
WTEC II dashboard cable assembly (para
7-10) or WTEC III dashboard cable assembly
(para 7-11).
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to connector PX6 socket 1.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire
3020 from connector PX6 socket 1 to
connector PX17A socket 2 (para 2-45) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(5) If continuity is present, replace OIL PRESS
gage (para 7-14).
(6) Connect connector PX24 to dimmer switch
connector.
(7) Connect connector clamp on dimmer
switch connector.
(8) Connect connector PX6 to OIL PRESS
gage connector.
(9) Connect connector clamp on OIL PRESS
gage connector.
(10) Install instrument panel assembly (para
7-15).
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |