CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector PX6 pin 4.
(3) Connect negative (-) probe of multimeter to
known good ground and note reading on
multimeter.
(4) If continuity is not present, repair wire 36
from connector P31 socket 11 to connector
P32 socket 2 (para 2-45) or engine control
cable assembly (para 7-80).
(5) If continuity is present, repair wire 36 from
connector J31 pin 11 to connector PX6 pin
4 (para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(6) Connect connector J31 to connector P31.
(7) Connect connector PX6 to engine OIL
PRESS gage connector.
(8) Connect connector clamp to engine OIL
PRESS gage connector.
(9) Install instrument panel assembly
(para 7-15).