TM 9-2320-366-20-1
RESISTANCE TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector PX6 pin 4.
(3) Connect negative (-) probe of multimeter to
known good ground and note reading on
multimeter.
(4) If 202-243 ohms resistance is not
present, go to step 4 of this fault.
RESISTANCE TEST
(1) Start engine (TM 9-2320-366-10-1).
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
connector PX6 pin 4.
(4) Connect negative (-) probe of multimeter to
known good ground and note reading on
multimeter.
(5) If 90-130 ohms resistance is not present,
replace engine oil pressure transmitter
(para 7-49).
(6) If 90-130 ohms resistance is present,
replace engine OIL PRESS gage (para 7-14).
(7) Shut down engine (TM 9-2320-366-10-1).
(8) Connect connector PX6 to engine OIL
PRESS gage connector.
(9) Connect connector clamp to engine OIL
PRESS gage connector.
(10) Install instrument panel assembly
(para 7-15).
Change 2
|