e6. ENGINE CRANKS BUT DOES NOT START (CONT)
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
on following page.
8.
Voltage Test or
Fuel quantity OK.
STE/ICE-R Test #89
Fuel/water separator primed.
Is 24 VDC present at
REASON FOR QUESTION
Air cleaner hose or tube OK.
terminal board TB1 position
Start inhibit pushbutton switch
If 24 VDC is not present, wire
59?
OK.
1690 is faulty. If 24 VDC is
Relay K19 OK.
present, wire 1462 is faulty.
POSSIBLE PROBLEMS
Faulty dashboard cable
NO
assembly.
Faulty engine control cable
assembly.
Repair wire 1690 from terminal board
TB1 position 61 on PDP to circuit breaker
CB79 socket 5 on PDP (para 2-45) or replace
YES
WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
Repair wire 1462 from terminal board TB1
position 59 on PDP to relay K19 socket
87A on PDP (para 2-45) or replace WTEC II
dashboard cable assembly (para 7-10) or
WTEC III dashboard cable assembly (para
7-11).