TM 9-2320-366-20-1
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
relay K19 terminal 87a.
(3) Connect negative (-) probe of multimeter to
relay K19 terminal 30 and note reading on
multimeter.
(4) If continuity is not present, replace relay
K19 (para 7-9).
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
VOLTAGE TEST
(1) Set multimeter to volts DC.
(2) Connect positive (+) of multimeter to
relay K19 socket 30 on PDP.
(3) Connect negative (-) probe of multimeter to
ground.
(4) Position master power switch to on (TM 9-
2320-366-10-1) and note reading on
multimeter.
(5) If 24 VDC is not present, go to step 8 of this
fault.
(6) Position master power switch to off (TM 9-
2320-366-10-1).
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |