TM 9-2320-366-20-1
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
VOLTAGE TEST
(1)
Set multimeter to volts dc.
(2)
Connect positive (+) probe of multimeter to
terminal lug TL28 on fuel solenoid.
(3)
Connect negative (-) probe of multimeter to
ground.
(4)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(5)
If 24 vdc is not present, go to step 3 of
this fault.
(6)
Position master power switch to off
(TM 9-2320-366-10-1).