TM 9-2320-366-20-1
e4. 24 VDC CIRCUITS DO NOT OPERATE (CONT)
CAUTION
Read CAUTION
KNOWN INFO
TEST OPTIONS
on following page.
15.
Continuity Test or
Service drive lights OK.
STE/ICE-R Test #91
Circuit breaker CB70 OK.
Is continuity present from
REASON FOR QUESTION
Batteries OK.
relay K2 socket 86 on PDP
100 AMP reverse polarity relay
If continuity is not present,
to connector PX17 socket
OK.
wire 1548 is faulty. If
1?
100 AMP reverse polarity relay
continuity is present wire 1586
to power distribution panel
is faulty.
(PDP) 24 VDC cable OK.
Battery to 100 AMP reverse
polarity relay 24 VDC cable
OK.
200 AMP reverse polarity
relay OK.
NO
200 AMP terminal block OK.
Battery to 200 AMP terminal
block 24 VDC cable
Repair wire 1548 from connector PX17 socket 1
assembly OK.
to relay K2 socket 86 on PDP (para 2-45) or
200 AMP terminal block to
YES
replace WTEC II dashboard cable assembly
reverse polarity relay 24
(para 7-10) or WTEC III dashboard cable
VDC battery cable OK.
assembly (para 7-11).
200 AMP terminal block to
reverse polarity relay 24
VDC load cable OK.
200 AMP terminal block to
power distribution panel
(PDP) 24 VDC cable OK.
Master power switch OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
assembly.
Repair wire 1586 from connector PX17 socket 5
to circuit breaker CB70 socket 4 on PDP (para 2-45)
or replace WTEC II dashboard cable assembly (para 7-10)
or WTEC III dashboard cable assembly (para 7-11).
2-284.12
Change 1
|