TM 9-2320-366-20-1
CONTINUITY TEST
(1) Remove circuit breaker CB36 from PDP.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter
to relay K2 socket 87 on PDP.
(4) Connect negative (-) probe of multimeter to
circuit breaker CB36 socket 6 on PDP and
note reading on multimeter.
(5) If continuity is not present, repair wire
1604 from relay K2 socket 87 on PDP to
bus bar X6 on PDP (para 2-45) or replace
WTEC II dashboard cable assembly (para
7-10) or WTEC III dashboard cable
assembly (para 7-11).
(6) If continuity is present, replace bus bar X6
on PDP or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(7) Install circuit breaker CB36 in PDP.
(8) Install relay K2 in PDP.
(9) Install power distribution panel (PDP) cover
(para 16-2).
(10) Connect batteries (para 7-57).