CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to terminal lug TL52.
(3) Connect negative (-) probe of multimeter to
terminal lug TL48 and note reading on
multimeter.
(4) If continuity is not present, replace
battery to shunt cable assembly (para
7-76) .
(5) If continuity is present, replace starter to
chassis ground cable (para 7-133).
(6) Install terminal lug TL52 on shunt with
lockwasher and screw.
(7) Position air hose on intake air cleaner
boot with clamp.
(8) Tighten clamp to 36-48 lb-in. (4-5 N.m).
(9) Raise spare tire (TM 9-2320-366-10-1).
(10) Connect batteries (para 7-57).