e3. 12 VDC AND 24 VDC CIRCUITS DO NOT OPERATE (CONT)
KNOWN INFO
TEST OPTIONS
10.
Circuit breaker CB70 OK.
Continuity Test or
Battery(ies) OK.
STE/ICE-R Test #91
Is continuity present from
Cab to chassis ground strap
REASON FOR QUESTION
terminal lug TL52 to
OK.
If continuity is not present,
terminal lug TL48?
PDP to cab ground cable OK.
battery to shunt cable
Shunt OK.
assembly is faulty. If
Starter to shunt 24 VDC
continuity is present starter
cable OK.
to chassis ground cable is
POSSIBLE PROBLEMS
faulty.
Faulty battery to shunt cable
assembly.
NO
Faulty starter to chassis
ground cable.
Replace battery to shunt
YES
cable assembly (para 7-76).
Replace starter to chassis
ground cable (para 7-133).