TM 9-2320-366-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back or not
capable of making good contact.
CONTINUITY TEST
(1) Disconnect connector clamp from
connector P116.
(2) Disconnect connector P116 from WTEC III
transmission ECU connector.
(3) Set multimeter to ohms.
(4) For each line of Table 2-8.3. Connector
PX33 Ground Continuity Test perform the
following:
(a) Connect positive (+) probe of
multimeter to connector PX33 socket.
(b) Connect negative (-) probe of
multimeter to connector P116
position and not reading on
multimeter.
(5) If continuity is not present on either wire in
Test repair wire (para 2-45) or replace
WTEC III dashboard cable assembly
(para 7-11).
(6) Install PDP on dashboard with three
screws.
(7) Connect connector P116 to WTEC III
transmission ECU connector.
(8) Connect connector clamp to connector
P116.
Table 2-8.3. Connector PX33 Continuity Test
Connector PX33
Connector P116
Wire
Socket
Socket
P
32
143
L
15
176
A
5
170
B
6
171
C
7
172
D
8
173
E
9
174
S
14
180
M
10
175
N
3
124
R
16
136
Change 1
2-261
|