TM 9-2320-366-20-1
Table 2-1. Preventive Maintenance Checks and Services (Cont)
Location
Item
Interval
Item to be
Procedure
Not Fully
No.
Checked or
Mission
Serviced
Capable If:
Semiannual
Check all engine wiring for signs of fraying,
Wiring is burned,
37
ENGINE
chafing, cracking, and burnt insulation.
cracked, frayed,
WIRING
or broken.
a.
Inspect air compressor and air compressor
a. Class III leak
governor for leaks and loose hardware.
is evident or
hardware is
missing or loose.
b.
Inspect air compressor oil tube for leaks and
b. Class III leak,
kinks/bends which would cause a restriction.
kinks or bends
are evident.
Semiannual
38
AIR COM-
c.
Check air compressor coolant tubes for leaks
c. Class III leak,
PRESSOR
and kinks/bends.
kinks or bends
AND
are evident.
GOVER-
NOR
2-41
|