TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
(2) Remove ETHER START switch (2)
from panel (3).
NOTE
Tag and mark wires before removing.
(3) Remove two screws (4),
lockwashers (5), and wires (6) from
ETHER START switch (2).
b. Installation.
(1) Install two wires (1) to ETHER START
switch (2) with two screws (3) and
lockwashers (4).
(2) Adjust jamnut (5) until there is
approximately 1/4 in. (6 mm) of
threads between jamnut and end of
threaded portion of ETHER START
switch (2).
(3) Install ETHER START switch (2) in
panel (6).
7-365
|