TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
c.
Assembly.
NOTE
Do step (2) for M978 only.
(2) Install fire extinguisher bracket (5) on battery box (6) with three screws (7), lockwashers (8), and
nuts (9).
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive,
solvent, or sealing compound gets on
skin or clothing, wash immediately with
soap and water.
NOTE
Do steps (2.1) and (2.2) for arctic
q
kit battery box only.
Do step (2.1) for M978 only.
q
(2.1) If installing new insulation (9.1), cut
clearance holes in insulation to allow for fire
extinguisher bracket mounting hardware.
(2.2) If removed, apply adhesive to nine pieces of
insulation (9.1 thru 9.5) and install in battery
box (6).
7-341
Change 2
|