TM
9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-48. AUXILIARY PUMP JUNCTION BOX ASSEMBLY REMOVAL/INSTALLATION (M978)
(CONT).
(10) Connect four wires (3), wire (15), and
wire (18) on relay (17) with four
screws (22).
(11) Install gasket (23) and cover (24) on junction box (4)
with four lockwashers (25) and screws (26).
c. Follow-on Maintenance.
(1) Install pump module left side access panel
(para 16-48).
(3) Recirculate fuel using AUXILIARY PUMP
(TM 9-2320-279-10).
END OF TASK
|