7-48. AUXILIARY PUMP JUNCTION BOX ASSEMBLY REMOVAL/INSTALLATION (M978)
(CONT).
(3) Position pump (5) on wheel
well (6).
(4) Install pump (5) with four
screws (7), washers (8), and
nuts (9).
WARNING
Adhesives, solvents, and sealing compounds can burn
easily, can give off harmful vapors, and are harmful
to skin and clothing. To avoid injury or death, keep
away from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing compound gets on
skin or clothing, wash immediately with soap and
water.
(5) Apply pipe thread sealing compound to threads of
adapter (10) and two plugs (11 and 12).
(6) Install adapter (10) and two plugs (11 and 12) in
junction box (4).