TM
9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
(7) Remove four locknuts (19), four
washers (20), and four screws (21)
from AUXILIARY PUMP (22) and
wheel well (23).
(8) Move AUXILIARY PUMP (22) down
for clearance.
(9) Remove junction box (5) from
AUXILIARY PUMP (22).
b. Installation.
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(1) Apply pipe thread sealing compound to
threads of pipe nipple (1) on AUXILIARY
PUMP (2).
(2) Thread wires (3) injunction box (4), and
install junction box on pipe nipple (1).
7-153
|