7-35. MAGNETIC SWITCH REMOVAL/INSTALLATION (CONT).
(3) Connect two wires (8) with
lockwashers (9) and nuts (10).
Tighten nuts to 30 to 35 in-lb
(3.4 to 4.0 Nm).
(4) Install heater compartment covers (11 and
12) with 11 screws (13).
c. Follow-on Maintenance.
(2) Check operation of main light switch
(TM 9-2320-279-10).
END OF TASK