TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
b. Installation.
(1) Install magnetic switch (1) and wire (2) with
washer (3) and two screws (4).
(2) Install two wires (2 and 5) with two
lockwashers (6) and nuts (7). Tighten
nuts to 20 to 25 in-lb (2.25 to 2.8 Nm).