TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
a.
Removal.
(1)
Pull light socket (1) from water
temperature gage (2).
NOTE
Tag and mark wires before
disconnecting.
Some trucks have wires connected to
three terminals. Some trucks have
wires connected to two terminals.
(2)
Disconnect three wires (3) from
terminals (4).
(3)
Remove two nuts (5),
lockwashers (6), and bracket (7).
(4)
Pull water temperature gage (2)
from instrument panel (8).
(5)
Remove three nuts (9),
lockwashers (10), and three
terminals (4) from water
temperature gage (2).
b.
Installation.
(1)
Install three terminals (4),
three lockwashers (10), and
nuts (9) on water
temperature gage (2).
(2)
Install water temperature gage
(2) and bracket (7) in
instrument panel (8).
(3)
Install two nuts (5) and lockwashers (6)
to secure water temperature gage (2)
and bracket (7) on instrument panel (8).
(4)
Connect three wires (3) to water temperature gage (2).
(5)
Push light socket (1) into back of water temperature gage (2).
c.
Follow-on Maintenance.
(2) Start engine and check operation of water temperature gage (TM 9-2320-279-10).
(3) Shut off engine (TM 9-2320-279-10).
END OF TASK
Change 4
|