TM 9-2320-279-20-1
Cooling System Maintenance Instructions (Cont)
6-8. LEFT THERMOSTAT, COVER, AND HOUSING REMOVAL/INSTALLATION (CONT).
b.
Installation.
WARNING
Adhesives, solvents, and sealing compounds
can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To
avoid injury or death, keep away from open
fire and use in well-ventilated area. If
adhesive, solvent, or sealing compound gets
on skin or clothing, wash immediately with
soap and water.
(1)
Coat threads of plug (1) with pipe thread
sealing compound and install in
thermostat housing (2).
(2)
Install two clamps (3), hose (4), gasket (5),
and thermostat housing (2).
(3)
Install three screws (6, 7, and 8),
lockwasher (9), and washer (10).
(4)
Tighten two clamps (3).
(5)
Coat threads of fanstat (11) with pipe thread sealing compound. Install fanstat (11) and two
air lines (12).
(6) Coat threads of water temperature sending unit (13) with pipe thread sealing compound.
Install water temperature sending unit, wire (14), lockwasher (15), and nut (16).
(7) Coat threads of alarmstat (17) with pipe thread sealing compound. Install alarmstat (17).
(7.1) Apply thread locking compound to alarmstat (17). Install wire (18), lockwasher (19), and nut
(20) on alarmstat (17).
Change 8
|