2-16. SIMPLIFIED TEST EQUIPMENT FOR INTERNAL COMBUSTION ENGINES
INTRODUCTION
q
The STE/ICE VTM is made to perform a test by setting the TEST SELECT switches to
the test number and pressing the TEST button. For some tests, an offset test is required before the test
itself can be performed. This is done by selecting the number of desired test and holding the TEST button
down until the VTM displays the prompting message CAL.
The offset test cancels characteristic differences in the VTM, test leads, and transducers. It zeros the
meter. Once the offset test is performed, the VTM automatically corrects for the offset before displaying
measured values. The displayed offset value should be checked against limits on the Vehicle Test Card. If
the displayed value is outside these limits, either the transducer or the test cable is faulty and must be
replaced. This is another form of self-test. Offset tests are done in both the DCA and TK modes of
operation. At the beginning of the DCA mode, all offset test numbers are dialed into the VTM. In the TK
mode, the offset is performed when each transducer is connected. All tests requiring offset are identified
by a star(*) on the flip cards and by OFFSET LIMITS on the Vehicle Test Cards. The offset test is performed
with the test probe cable or transducer connected to the VTM. Care should be taken that no stimulus is
being applied to the transducer. Test probe cable leads should be shorted together. To perform an offset
test, dial the test number into TEST SELECT. Press and hold TEST button until the prompting message
CAL appears on the display. In a few seconds after release of TEST button, a number will appear. This is
the measured offset value associated with the test probe cable or transducer or transducer and cable.
These tests are used to change (or control) the way a vehicle testis displayed, or
(4) Control
the way it is run. There are five (5) control tests.
01 Interleave (alternates RPM with next test measurement)
02 Display minimum value for next test
03 Display maximum value for next test
04 Display peak-to-peak value for next test
q
05 Initiate S1 full power simulation (Not applicable to M977 series vehicles).
Control tests 01, 02, 03, and 04 specify the action to be taken by the next test only. Any test dialed in after
the test that is being controlled will cancel the effect of the test.
This test alternately measures engine speed and a second parameter such as
Interleave
fuel pressure or alternator voltage. To start interleave, dial 01 into the Test SELECT switches and press the
TEST button. The prompting message PASS will signal the operator to dial in the second test number and
again press the TEST button.
(Test 02). This test displays the minimum value measured during a test. To start
Minimum
a minimum value display, dial 02 into the TEST SELECT switches and press the TEST button. The
prompting message PASS will signal the operator to dial in the desired test number and again press the
TEST button. The minimum value is displayed and updated whenever a lower minimum value is measured.
Entering 02 and the test number again will reset the process and a new minimum value will be displayed.
03). This test displays the maximum value measured during a test. To
Maximum
start a maximum value display, dial 03 into the TEST SELECT switches and press the TEST button. The
prompting message PASS will signal the operator to dial in the desired test number and again press the
TEST button. The maximum value is displayed and updated whenever a higher maximum value is
measured. Entering 03 and the test number again will reset the process and a new maximum value will be
displayed.
Peak-to-Peak Value (Test 04). This test displays the peak-to-peak value of
output
volts (82), 45-volts DC (89), 1500 amps DC (90), and battery volts (67). Electrical peak-to-peak is for
measuring dwell variation. To start a peak-to-peak measurement, dial 04 into the TEST SELECT switches
and press the TEST
The prompting message PASS will signal the operator to dial in one of the four
test numbers (82, 89, 90, 67) and again press the TEST button.