(1) Pressure Transducers. The pressure transducers have a small breather hole on the side of the
housing which should be kept unplugged. Do not use high pressure shop air to blow out the 25 psig
transducer.
Make sure that the slotted hole in the engine tachometer drive shaft is clear
and not hard packed with lubricant before installing the pulse tachometer.
Threaded Adapters. Look at threaded fittings carefully to avoid engaging straight threads with
pipe threads. Each measurement device (transducer) in the transducer kit
its own identification
resistor. The VTM uses this identification resistor to check that the correct transducer is connected for the
measurement being made. If the correct transducer is not connected, error code EO02 will be displayed.
of Readouts. The following paragraphs describe and show the different types of readouts
that can occur during testing.
(1) Status Readout. A status readout keeps the operator informed of what is happening. For
example, .8.8.8.8 is displayed each time the power switch is pushed on. It means that power is applied,
and that all elements of the display are operative. It changes to ---- 1.5 seconds later, indicating that the
2-12. -
The
readout
are described in
VTM is ready to be used for
2-12. Status Readout
VTM Readout
Interpretation
A readout of .8.8.8.8 appears for 1 to 2 seconds each time that the power is applied
.8.8.8.8
to the VTM. It means that there is power to the VTM, and that all elements of the
readout display are operative.
A readout of ---- indicates the following:
(1) After power turn-on, signifies that the VTM is ready for testing.
(2) During a compression unbalance test, signifies testing is in progress.
.9.9.9.9
A readout of .9.9.9.9 indicates that the VTM is reading a test value beyond the
range of its measurement capability. Either the wrong test number is selected for
the parameter being measured, or there is a fault in the vehicle.
PASS
A PASS or FAIL readout is the result of a test that checks the condition of a
FAIL
component being measured. A PASS/FAIL readout means just that - the component
either passes the test or fails the test.