TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
2-15. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 2-9.
Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ARCTIC HEATER KIT (CONT)
9. ARCTIC HEATER DIAGNOSTIC TROUBLESHOOTING (ORGANIZATIONAL LEVEL) (MODEL B)
(CONT).
Step 41.
If Fault Code Retrieval Device (FCRD) is not available, go to Step 44.
Step 42.
If same fault code is displayed, notify the supervisor.
Step 43.
If different fault code is displayed, go to Step 1.
NOTE
Perform Steps (44) and (45) only if referred here from another step in this procedure.
Step 44.
Arctic heater control unit is either faulty or in lockout (fault code 015 or 050), notify the
supervisor.
Step 45.
Direct Support level troubleshooting required, notify the supervisor.