TM 9-2320-279 -20-1
Troubleshooting Malfunctions (Cent)
TROUBLESHOOTING INSTRUCTIONS
2-15.
2-9. Troubleshooting (Cent)
Test or Inspection
Corrective Action
TANKER SYSTEM
I 1. TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL
FUSE
FUSED
LEAD
TA1 87420
NOTE
From this point on, do not install junction box covers, gage covers, or operate tanker
1, sheets 3 and 4
until problem is solved and this manual says to do so. Refer to
for M978 Electric Diagram.
Step 6. Remove control junction box cover (para 7-49). Disconnect fuse holder and look for blown
fuse.
Replace blown fuse.
and APC AUXILIARY PUMP
Step 7. Remove fused lead from TLI TANK LEVEL
CONTROL switches. Check wire resistance.
If resistance is more than zero ohms between fuse holder and wire terminals,
replace fused lead.
switch. Disconnect connectors. Check
Step 8. Check for defective TLI TANK LEVEL
switch is in the ON position.
switch resistance when TLI TANK LEVEL
If resistance is more than zero ohms, replace defective TLI TANK LEVEL
switch (para 7-49), install TLI TANK LEVEL INDICATOR gage cover
|