TM 9-2320-279 -20-1
Troubleshooting Malfunctions (Cent)
2-9. Troubleshooting (Cent)
Test or Inspection
Corrective Action
TANKER SYSTEM
Il.
TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL.
E
Step 1. Check for jammed needle on TLI TANK LEVEL
gage.
dial face with hand.
Replace jammed TLI TANK LEVEL INDICATOR gage (para 7-86).
NOTE
The
tanker may be equipped with one of two types of fuel level sensors.
q
One
Each particular type of sensor has its own unique tank level indicator
type, Model A, has a plastic fuel level sensor while the other type, Model B, has a
brass fuel level sensor. Refer to TM 9-2320-279-34P for correct ordering
instructions.
manhole must be closed when testing Model A tank level indicator.
Model A fuel level sensor has phototransistors that are affected by light.
. Fuel level sensor will sometimes not read foamy fuel levels.
Step 2. Check for foamy fuel in tank. Open manhole (TM 9-2320-279-10).
Wait until foam settles before going further.
Step 3. Check for broken fuel level sensor in tank.
Replace broken fuel level sensor (para 7-88).
|