TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
Table 2-9.
Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
5. AUXILIARY PUMP WILL NOT PUMP FUEL (CONT).
Step 7.
Check for defective auxiliary pump relay ground wire. Disconnect blue wire from auxiliary
pump junction box and relay terminal A5. Check resistance of blue wire.
If resistance is more than zero ohms, replace wire, install main, control, and
auxiliary pump junction box covers (paras 7-47, 7-48, and 7-49).
Step 8.
Connect batteries (para 7-91). Check for defective auxiliary pump relay. Set APC AUX-
ILIARY PUMP CONTROL switch to ON.
If AUXILIARY PUMP does not run, replace auxiliary pump relay (para 7-48), install
main and control junction box covers (paras 7-47 and 7-49).