TM
9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
2-15. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 2-9. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
MATERIAL HANDLING CRANE (M983) (CONT)
2. CRANE BOOM MOVES SLOWLY (CONT).
Step 3. Check for plugged strainers or filter.
Clean or replace top strainer or filter (para 13-11).
Step 4. Check hydraulic lines from hydraulic pump to crane for looseness or damage, starting at
crane connections.
Tighten loose connections, add oil as required (LO 9-2320-279-12).
If lines are damaged, notify the supervisor.
Step 5. If problem has not been solved, notify the supervisor.
3. OUTRIGGER CYLINDERS WILL NOT RETRACT.
Step 1. Check for loose or damaged hydraulic lines.
Tighten loose lines, add oil as required (LO 9-2320-279-12).
If lines are damaged, notify the supervisor.
Step 2. If problem remains, notify the supervisor.
MATERIAL HANDLING CRANE (M977, M985, M984E1)
1.
CRANE WILL NOT OPERATE.
Step 1. Check for faulty hydraulic system operation.
Refer to HYDRAULIC SYSTEM Troubleshooting.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |